Stainless Steel - Installation
16
®
®
INSTALLATION OVERVIEW
NEW CONSTRUCTION
REAR MOUNTED
WITH DUCT COLLAR
FACE MOUNTED
WITH Z-BRACKET
CEILING DIFFUSER - FACE MOUNTED
with INSTALLATION PLATE
CEILING DIFFUSER
DUCT MOUNTED
S-VENT
®
DIFFUSER MODEL
SSV432
1. Drill all holes necessary for proper positioning of the
installation plate.
2. Attach the installation plate to the ceiling by welding or
using screws (by others).
3. Using approved security screws
(by others)
, install
the diffuser.
4. As necessary, seal any gaps around the faceplate using
an approved security sealant
.
S-VENT
®
DIFFUSER MODEL SSV432
1. Position the diffuser into hole in ceiling, ensuring it is
firmly set at the faceplate edges.
2. Attach ductwork to diffuser, guarding against any
screws penetrating the S-channel of the diffuser.
3. Firmly secure the ductwork to maintain a tight fit of
the diffuser faceplate flange to the ceiling.
4. As necessary, seal any gaps around the faceplate
using an approved security sealant.
S-VENT
®
MODELS SSV22, SSV23, SSV26,
SSV49
and SSV42
1. Put threaded rods into coupling nuts at rear of grille
face.
2. Set grille into opening, ensuring that it is centered in
position.
3. Position duct collar over the threaded rod and secure
the washers and nuts.
4. As necessary, seal any gaps around the faceplate
using an approved security sealant.
S-VENT
®
MODELS SSV22, SSV23, SSV26
and SSV42
1. Insert Z-bracket into opening, ensuring it is properly
oriented.
2. Position duct collar and then securely connect the
Z-bracket and duct collar using the threaded rod
with the coupling nuts.
3. After all interior finishing is complete, install the
grilles using approved security screws (by others).
4. As necessary, seal any gaps around the faceplate
using an approved security sealant.
IMPORTANT It is the specifier’s responsibility to properly configure the
HVAC system to meet the appropriate level of comfort, safety, security and detention